OMD- 2008

OMD- 2008 - 15 ppm Bilge Alarm IMO Resolution MEPC.107
Verwendung: 

15 ppm Bilge Alarm geprüft nach der IMO Resolution MEPC.107 (49)

Spezifikation: 
PropertyValue
Range (measurement & indication)0 - 30 ppm, Trend up to 50ppm
Range (IMO specification)0 - 15 ppm (according IMO regulations)
Accuracybetter than IMO MEPC.107(49)
Electrical power supply24V - 240V, AC or DC, Automatic Voltage Selection
Electrical power consumption< 10 VA
SampleOily water from separator outlet, 0,1 - 4 l/min
Sample temperature range+1°C  to +65°C
Sample connectionsR 1/4" Female
Alarm 1 & 2 Set Points1 - 15ppm (independently adjustable)
Alarm 1 operating delay for annunciation1 - 540 sec
Alarm 2 operating delay for control 1 - 10 sec
Alarm contacts2 independently adjustable switchover contacts
Alarm contact operation modeDe-energized in Alarm State
Alarm contact ratings3A, 240V each
Alarm output0 - 20 mA or 4 - 20 mA, for 0-30ppm reversible, ext. Load<150Ω
DisplayGraphic Display
Ambient temperature+1°C to +55°C
Class of protectionIP 65
Dimension360 x 240 x 100 mm (WxHxD)
Weight5,4 kgs